Research

Research Infrastructures

Laboratoraties CREDEAU


At Polytechnique Montréal, the FCI-MELS grant has enabled the construction of analysis spaces, test wells, a Level 2 room for work on pathogenic organisms, fixed pilot installations, cold rooms and temperature controlled rooms, analytical chemistry, microbiology and environmental engineering rooms, and test halls, for an area of ​​800 m2 approximately. These spaces are dedicated to drinking water and wastewater treatment projects and complement existing facilities. Two laboratories for treating pulp and paper sludge by bio-drying are also used by CREDEAU researchers. The facilities available at the École de Technologie Supérieure, for a total area of ​​approximately 800 m2, include a pilot hall for large-scale studies, an instrumentation laboratory and a wet laboratory for analysis, a microbiology laboratory, physics and weighing, a controlled environmental chamber to simulate seasonal conditions and a clean room for research in biotechnology and nanotechnology. A product and process design laboratory was built at the Université de Montréal at the André-Aisenstadt Pavilion in 2014. The computerized laboratory is equipped with the BALAS process simulation software to obtain off-site real time. A phytotechnology research infrastructure was also installed at the Montréal Botanical Garden in 2016. It will be used for phytotechnology work carried out by the Université de Montréal research team to develop water treatment processes. waste and sludge with plants.

Institution
  • Polytechnique Montréal
  • École de technologie supérieure (ÉTS)
  • Université de Montréal (UdeM)
Location
Montréal, Québec
Contact person
Shokoufeh Nour, Director of CREDEAU laboratories
shokoufeh.nour@polymtl.ca, 514 340-4711, poste 3430
Associated axis :
  • Axis Uses of water
    Theme 1: Water needs and uses of cities
More info de Laboratoraties CREDEAU

Mobile pilot unit for activated sludge


The AS+ unit is composed of activated sludge (AS) treatment and a membrane process. Several configurations are possible: - Activated sludge "classic" - Use of media with or without activated sludge - RBS (Sequential Biological Reactor) - BRM (Membrane Bioreactor) - FPB (Low Sludge Production)

Institution
  • Polytechnique Montréal
Location
(mobile) Montréal, Québec
Contact person
Shokoufeh Nour, Director of CREDEAU laboratories
shokoufeh.nour@polymtl.ca, 514 340-4711, ext. 3430
Associated axes :
  • Axis Uses of water
    Theme 1: Water needs and uses of cities
  • Transversal axis: Governance and management
    Theme 2: Risks and disrupters of governance
More info de Mobile pilot unit for activated sludge

Mobile pilot unit for advanced treatment


This innovative unit consists of 4 platforms. The objective is the elimination of dissolved pollution by the following processes: - Pre-treatment by ballast settling (Actiflo-MiniTM) - Ozonation or advanced oxidation (ozone - UV) - Adsorption / biodegradation on activated carbon powder (CAP) - 4 parallel streams of biomembranes under pressure - 2 parallel dies of submerged biomembranes

Institution
  • Polytechnique Montréal
Location
(mobile) Montréal, Québec
Contact person
Shokoufeh Nour, Director of CREDEAU laboratories
shokoufeh.nour@polymtl.ca, 514 340-4711, ext. 3430
Associated axes :
  • Axis Uses of water
    Theme 1: Water needs and uses of cities
  • Transversal axis: Governance and management
    Theme 2: Risks and disrupters of governance
More info de Mobile pilot unit for advanced treatment

Mobile pilot unit for biological treatment


This pilot unit allows biofiltration on floating media (BiostyrTM) coupled to an MBBR process including feed pump, biofiltration column and treated water storage tanks and sludge. The BiostyrTM unit is used in secondary treatment at a flow rate of 0.35 m3 / h (filtration rate 5 m / h).

Institution
  • Polytechnique Montréal
Location
(mobile) Montréal, Québec
Contact person
Shokoufeh Nour, Director of CREDEAU laboratories
shokoufeh.nour@polymtl.ca, 514 340-4711, ext. 3430
Associated axes :
  • Axis Uses of water
    Theme 1: Water needs and uses of cities
  • Transversal axis: Governance and management
    Theme 2: Risks and disrupters of governance
More info de Mobile pilot unit for biological treatment

Mobile pilot unit for conventional treatment


This unit groups conventional processes for the treatment of drinking water: - Pumping system and pretreatment - Conventional flocculation and settling - Weighted decantation (ActifloTM unit) - Granular filtration, conventional or direct (4 filtration columns) - Ozonation

Institution
  • Polytechnique Montréal
Location
(mobile) Montréal, Québec
Contact person
Shokoufeh Nour, Director of CREDEAU laboratories
shokoufeh.nour@polymtl.ca, 514 340-4711, ext. 3430
Associated axes :
  • Axis Uses of water
    Theme 1: Water needs and uses of cities
  • Transversal axis: Governance and management
    Theme 2: Risks and disrupters of governance
More info de Mobile pilot unit for conventional treatment

Mobile pilot unit for physicochemical treatment


This mobile pilot unit made the weighted decantation (ActifloTM) including a sieve, a flocculation basin, three mechanical mixers, a static decanter and a dosing system (coagulant, soda, polymer). ActifloTM can be used in primary or tertiary treatment. Its treatment capacity is 2 to 6 m3 / h (speed of 40 to 120 m / h).

Institution
  • Polytechnique Montréal
Location
(mobile) Montréal, Québec
Contact person
Shokoufeh Nour, Director of CREDEAU laboratories
shokoufeh.nour@polymtl.ca, 514 340-4711, ext. 3430
Associated axes :
  • Axis Uses of water
    Theme 1: Water needs and uses of cities
  • Transversal axis: Governance and management
    Theme 2: Risks and disrupters of governance
More info de Mobile pilot unit for physicochemical treatment